All Trio systems require a 4 wire 240v line to be installed.
System Size (Gallons) | Type of Panel | Outlet Type | # of Outlets | Breaker (Amps) |
15/20/30 | Single Batch | NEMA 14-30 | 1 | 30 |
15/20/30 | Double Batch | NEMA 14-30 | 2 | 2 x 30 |
50 | Single Batch | NEMA 14-30 | 2 | 2 x 30 |
50 | Double Batch | NEMA 14-30 | 4 | 4 x 30 |
- The 10/15/20 and 30 gallon systems come with a single 5500 Watt element in the boil kettle and the hot liquor tank.
- The 50 gallon systems come with 2x 5500 Watt elements in both the boil kettle and hot liquor tank.
- Trio Systems are available in single phase only (no three phase design available)
- 6 Foot power cord included (from electrical panel to outlet)
- "Element" circuit is L6-30R 3-prong outlet and can handle heater load up to 25A / 6000W
"Pump" and "Aux" circuits are 5-15R 3-prong outlet and can handle load up to 1.5A / 180W
- NEMA 14-30 outlet (shown below)
*All electrical installations should be performed by a professional electrician.
*We recommend a GFCI breaker for added protection.
*Installed breaker must support neutral.